Precision of the optimized carbon monoxide rebreathing method to determine total haemoglobin mass and blood volume

Jérôme Durussel, Ramzy Ross, Prithvi Raj Kodi, Evangelia Daskalaki, Pantazis Takas, John Wilson, Bengt Kayser, Yannis Pitsiladis*

*Corresponding author for this work

    Research output: Contribution to journalJournal articlepeer-review

    13 Citations (Scopus)

    Abstract

    The aim of this study was to evaluate the influence of different apparatuses, procedures and calculations on the precision of the optimized carbon monoxide method. Total haemoglobin mass was determined twice on consecutive days in 11 subjects using both venous and capillary blood samples. To estimate loss of carbon monoxide due to exhalation, carbon monoxide concentration was measured by two portable carbon monoxide analysers (Fluke CO-220, Fluke, Norwich, UK and Pac 7000 Carbon Monoxide, Draeger Safety, Northumberland, UK) and alveolar ventilation was specified using an automated metabolic gas analysis system (Cosmed Quark b2, Cosmed, Rome, Italy). Blood volume was derived from total haemoglobin mass using haemoglobin concentration and haematocrit obtained in both the supine and the seated position. Two different formulae to calculate blood volume were also compared. Precision was good for both total haemoglobin mass and blood volume measurements performed on consecutive days (typical error < 2%). Using Fluke CO-220 analyser, an estimated alveolar ventilation and capillary blood, total haemoglobin mass (917±136 g) was similar when compared to the Pac 7000 Draeger CO-analyser (904±137 g; mean bias -13 g with 95% limits of agreement -26 to + 1 g, P=0.76), specified alveolar ventilation (911±132 g, mean bias -6 g with 95% limits of agreement -18 g to + 6 g, P =0.87) and venous blood (917±134 g, mean bias 0 g with 95% limits of agreement -38 to + 38 g, P=0.99), respectively. Blood volume determination was also not significantly affected by the supine vs. seated position (6.7±0.8 l vs. 6.6±0.8 l, P=0.56) but can deviate by ~0.6 l (P=0.01) depending on the formula applied. Thus, the good precision of the assessment of total haemoglobin mass and blood volume using the optimized carbon monoxide rebreathing method is not significantly influenced by the make of CO analyser, method of obtaining alveolar ventilation, blood sampling method and subject position, but should for longitudinal monitoring purposes use the same formula.

    Original languageEnglish
    Pages (from-to)68-77
    Number of pages10
    JournalEuropean Journal of Sport Science
    Volume13
    Issue number1
    Early online date1 Jan 2011
    DOIs
    Publication statusPublished - Jan 2013

    Scopus Subject Areas

    • Physical Therapy, Sports Therapy and Rehabilitation
    • Orthopedics and Sports Medicine

    User-Defined Keywords

    • Carboxyhaemoglobin
    • comparison of methods
    • measurement error

    Fingerprint

    Dive into the research topics of 'Precision of the optimized carbon monoxide rebreathing method to determine total haemoglobin mass and blood volume'. Together they form a unique fingerprint.

    Cite this