Abstract
Electrochemically activated glassy carbon electrodes adsorbed with anthraquinonesulfonate species showed potentiometric responses toward pH changes for pH range between 1 and 11, with a near Nernstian slope of about 56.4mV/pH and a lifetime of more than one month. The effects of electrode pretreatment and preparation conditions, as well as the effects of interfering ions on the electrode response were studied.
Original language | English |
---|---|
Pages (from-to) | 1160-1164 |
Number of pages | 5 |
Journal | Electroanalysis |
Volume | 8 |
Issue number | 12 |
DOIs | |
Publication status | Published - Dec 1996 |
Scopus Subject Areas
- Analytical Chemistry
- Electrochemistry
User-Defined Keywords
- Anthraquinone
- Glassy carbon
- ph