TY - JOUR
T1 - Investigation of interaction mechanism between polyvinyl chloride microplastics and phthalate acid esters using APGC-MS/MS
AU - Yu, Yanbin
AU - Wang, Linlin
AU - Yu, Qing
AU - Wu, Qianru
AU - He, Yu
AU - Cai, Zongwei
N1 - This work was supported by the National Natural Science Foundation of China (No. 22276034, 22036001).
Publisher Copyright:
© 2024 Elsevier B.V.
PY - 2025/1/1
Y1 - 2025/1/1
N2 - Phthalate acid esters (PAEs) are a kind of typical endocrine disruptors chemicals (EDCs). PAEs can be enriched, migrated and released into organisms through microplastics (MPs), causing high toxicological risks. This study presented an atmospheric pressure gas chromatography-tandem mass spectrometry (APGC-MS/MS) method for 10 PAEs trace analysis. Based on this method, the interaction mechanism between polyvinyl chloride microplastics (PVC MPs) and PAEs was explored. The established APGC-MS/MS method achieved 10 PAEs analysis in 14 min with the satisfied detection limit as low as 0.0025 μg/L and excellent linearity (R2 = 0.99868–0.99996). The interaction mechanism investigation showed that PVC MPs had high adsorption and desorption capacities for PAEs. The adsorption mechanism involves adsorption distribution, surface adsorption, hydrophobic interaction and intermolecular van der Waals force. Temperature, diffusion channels, pore filling, hydrophobicity and solubilization may be potential desorption mechanisms. Moreover, the intestinal environment of warm-blood organisms has the highest bioavailability of PAEs. Overall, this APGC-MS/MS method of PAEs had the virtue of simplicity, efficiency, reliability and sensitivity, and could serve as a potential tool for risk analysis of MPs and PAEs exposure.
AB - Phthalate acid esters (PAEs) are a kind of typical endocrine disruptors chemicals (EDCs). PAEs can be enriched, migrated and released into organisms through microplastics (MPs), causing high toxicological risks. This study presented an atmospheric pressure gas chromatography-tandem mass spectrometry (APGC-MS/MS) method for 10 PAEs trace analysis. Based on this method, the interaction mechanism between polyvinyl chloride microplastics (PVC MPs) and PAEs was explored. The established APGC-MS/MS method achieved 10 PAEs analysis in 14 min with the satisfied detection limit as low as 0.0025 μg/L and excellent linearity (R2 = 0.99868–0.99996). The interaction mechanism investigation showed that PVC MPs had high adsorption and desorption capacities for PAEs. The adsorption mechanism involves adsorption distribution, surface adsorption, hydrophobic interaction and intermolecular van der Waals force. Temperature, diffusion channels, pore filling, hydrophobicity and solubilization may be potential desorption mechanisms. Moreover, the intestinal environment of warm-blood organisms has the highest bioavailability of PAEs. Overall, this APGC-MS/MS method of PAEs had the virtue of simplicity, efficiency, reliability and sensitivity, and could serve as a potential tool for risk analysis of MPs and PAEs exposure.
KW - Adsorption
KW - APGC-MS/MS
KW - Desorption
KW - Phthalate acid esters
KW - Polyvinyl chloride microplastics
UR - http://www.scopus.com/inward/record.url?scp=85204958505&partnerID=8YFLogxK
U2 - 10.1016/j.talanta.2024.126942
DO - 10.1016/j.talanta.2024.126942
M3 - Journal article
AN - SCOPUS:85204958505
SN - 0039-9140
VL - 282
JO - Talanta
JF - Talanta
M1 - 126942
ER -